AWG (American Wire Gauge) is a standard measurement system used in wire sizing that defines the nominal diameter and cross-sectional area of electrical conductors. It is frequently encountered in the technical specifications of cables used in electronic devices, industrial wiring, defense systems and aerospace applications.

In the metric system, conductor cross-section is expressed directly in mm², whereas the AWG system uses a geometric numbering. As the AWG number increases, the conductor diameter and cross-sectional area decrease.

However, the right cable cannot be selected on the basis of the AWG or mm² value alone. Conductor material, strand construction, insulation properties, operating temperature, voltage rating and application-specific standards should be evaluated together.

## What Is AWG and What Does It Mean?

American Wire Gauge (AWG) is a measurement system that defines the nominal diameters and cross-sectional areas of solid round wires used as electrical conductors. The standard sizes and calculation principles of the system are defined in ASTM B258.

AWG uses a geometric rather than a linear scale. The ratio of conductor diameters between two consecutive AWG sizes is approximately 1.123.

According to this geometric relationship:

- When the AWG number increases by 3, the conductor cross-sectional area is roughly halved.
- When the AWG number increases by 6, the conductor diameter is roughly halved.
- As the AWG number decreases, the conductor cross-sectional area increases and, other conditions being equal, its electrical resistance per unit length decreases.
For example, a 16 AWG conductor has roughly twice the diameter and four times the theoretical cross-sectional area of a 22 AWG conductor.

The AWG value does not express the outer diameter of the cable including insulation, nor its current-carrying capacity directly.

## AWG to mm² Conversion Table

The table below shows the theoretical diameters and cross-sectional areas of conductors in the 10-30 AWG range found in electronic devices, defense systems and aerospace wiring.

- AWG
- Theoretical conductor diameter (mm)
- Theoretical cross-sectional area (mm²)
- 10 AWG
- 2.588
- 5.261
- 11 AWG
- 2.305
- 4.172
- 12 AWG
- 2.053
- 3.309
- 13 AWG
- 1.828
- 2.624
- 14 AWG
- 1.628
- 2.081
- 15 AWG
- 1.450
- 1.650
- 16 AWG
- 1.291
- 1.309
- 17 AWG
- 1.150
- 1.038
- 18 AWG
- 1.024
- 0.823
- 19 AWG
- 0.912
- 0.653
- 20 AWG
- 0.812
- 0.518
- 21 AWG
- 0.723
- 0.410
- 22 AWG
- 0.644
- 0.326
- 23 AWG
- 0.573
- 0.258
- 24 AWG
- 0.511
- 0.205
- 25 AWG
- 0.455
- 0.162
- 26 AWG
- 0.405
- 0.129
- 27 AWG
- 0.361
- 0.102
- 28 AWG
- 0.321
- 0.081
- 29 AWG
- 0.286
- 0.064
- 30 AWG
- 0.255
- 0.051
The values in the table are solid round conductor dimensions calculated from the AWG geometric relationship. Small differences may appear because of the rounding methods used in the ASTM B258 nominal tables. For the physical dimensions and actual cross-sectional areas of stranded conductors, the manufacturer’s datasheet should be used.

## How Is AWG to mm² Calculated?

The following geometric relationship is used to obtain the theoretical conductor diameter in millimeters from the AWG number:

d = 0.127 × 92(36 - n) / 39

Where:

- **d:** Theoretical conductor diameter in millimeters
- **n:** AWG number
- **0.127:** Reference diameter of a 36 AWG conductor in millimeters
Once the conductor diameter is calculated, the circular cross-sectional area is determined with the following formula:

A = π × d² / 4

Here, A is the theoretical conductor cross-sectional area in mm².

For example, the theoretical diameter of a 22 AWG solid conductor is calculated as approximately 0.644 mm and its cross-sectional area as 0.326 mm².

Some technical tables use a value of 0.324 mm² for 22 AWG. This difference comes from rounding the nominal diameter before the calculation versus using the theoretical formula result directly.

## What Is the Difference Between AWG and Metric Wire Sizes?

AWG and the metric system define conductor sizes through different series of sizes.

Metric conductors defined under IEC 60228 use nominal cross-sections such as 0.5 mm², 0.75 mm², 1 mm², 1.5 mm² and 2.5 mm². In the AWG system, conductor sizes are set according to a geometric number series.

For this reason, there is not always a one-to-one nominal size match between the two systems.

- AWG
- Theoretical cross-section
- Commonly encountered nearby metric sizes
- 24 AWG
- 0.205 mm²
- 0.25 mm²
- 22 AWG
- 0.326 mm²
- 0.34 / 0.35 mm²
- 20 AWG
- 0.518 mm²
- 0.5 mm²
- 18 AWG
- 0.823 mm²
- 0.75 / 1 mm²
- 16 AWG
- 1.309 mm²
- 1.5 mm²
- 14 AWG
- 2.081 mm²
- 2.5 mm²
- 12 AWG
- 3.309 mm²
- 4 mm²
The nearby metric sizes in the table do not mean a direct electrical or mechanical equivalent.

For example, replacing a 16 AWG cable with a 1.5 mm² cable should be evaluated separately in terms of the connector contact, crimp terminal, cable outer diameter, electrical resistance and the relevant project specification.

In aerospace and defense projects in particular, cable changes should not be made on the basis of a cross-section conversion alone.

## Does AWG Refer to the Cable Outer Diameter or the Conductor Diameter?

AWG expresses the conductor size, not the overall diameter of the cable including insulation.

When evaluating the physical dimensions of a cable, three different parameters need to be distinguished:

- **Conductor cross-sectional area (CSA):** The cross-sectional area of the metal conductor that carries the electrical current.
- **Conductor diameter:** The physical diameter of a solid conductor or of a stranded conductor bundle.
- **Cable outer diameter (OD):** The overall diameter including the conductor, insulation and, where present, shielding and the outer jacket.
In stranded conductors, the nominal AWG definition and the solid wire area calculated from the geometric relationship may not be exactly the same. The metal cross-section, strand construction and permitted conductor resistance should be verified from the relevant product specification.

### TE Connectivity 44A0211-22-2 product example

The 44A0211-22-2 cable in TE Connectivity’s RAYCHEM Spec 44 family is an example that shows this difference.

- Technical property
- Value
- Conductor size
- 22 AWG
- Conductor material
- Tin-plated copper
- Number of strands
- 19
- Individual strand size
- 34 AWG
- Conductor bundle diameter
- 0.79 mm
- Cable outer diameter
- 1.37 mm
- Voltage rating
- 1000 V
- Operating temperature
- -65 °C to +150 °C
The theoretical diameter of a 22 AWG solid conductor is approximately 0.644 mm. TE’s 44A0211-22-2 product page lists 19 strands of 34 AWG, a conductor bundle diameter of 0.79 mm and a cable outer diameter of 1.37 mm. The diameter limits and tolerances to be used in the design should be checked on the relevant product drawing.

This distinction matters when selecting connector backshells, cable seals, crimp terminals, heat shrink tubing and cable protection systems.

## How Does AWG Affect Current-Carrying Capacity?

The cross-sectional area of an electrical conductor directly affects its electrical resistance per unit length and the heat losses that occur under current.

The electrical resistance of a conductor is basically expressed with the following relationship:

R = ρ × L / A

This relationship is the basic approximation for the direct current resistance of a conductor with a uniform cross-section at constant temperature. Here, A is the metal cross-sectional area. Resistivity changes with temperature. In AC and high-frequency applications, frequency-dependent resistance and impedance effects are evaluated separately.

Where:

- **R:** Electrical resistance (Ω)
- **ρ:** Resistivity of the conductor material
- **L:** Conductor length
- **A:** Conductor cross-sectional area
Other conditions being equal, conductors with a lower AWG number have a larger cross-sectional area and a lower electrical resistance.

Since power loss in the conductor is expressed as P = I²R, an increase in current also increases the heat loss in the conductor.

The 22 AWG values in this table are based on the assumptions of a 70 °C ambient temperature, a bundle of 33 or more conductors for the 24-10 AWG range, use of no more than 20% of the bundle’s total current-carrying capacity, and an operating altitude of 60,000 ft. Under other conditions, the permitted current should be determined separately.

### Factors that determine current-carrying capacity

- Parameter
- Effect on current capacity
- Conductor material
- The electrical resistivity of the material affects conduction losses.
- Conductor plating
- Tin, silver or nickel plating may affect resistance and temperature performance.
- Temperature rating
- Sets the maximum permitted operating temperature of the cable.
- Ambient temperature
- Affects heat transfer from the conductor to its surroundings.
- Cable bundle
- Determines the thermal interaction of conductors that are grouped and loaded together.
- Operating altitude
- Affects air density and convective heat transfer.
- Cable length
- Affects total resistance and voltage drop.
- Connecting elements
- The current limits of connector and terminal contacts may restrict system capacity.
Table 11-9 in Chapter 11 of FAA AC 43.13-1B shows values of 3 A, 5 A and 6 A for the same 22 AWG copper conductor at temperature ratings of 105 °C, 150 °C and 200 °C respectively.

However, these values are based on specific assumptions such as a 70 °C ambient temperature, a bundle of 33 or more wires, defined loading conditions and an operating altitude of 60,000 ft.

Therefore, these values cannot be used as a general AWG ampacity table.

For conductor selection in aircraft EWIS wiring, SAE AS50881 and the SAE AIR6540 information report, which explains the selection method, are evaluated together with the applicable project requirements. For wiring inside electronic equipment, the relevant equipment specification should be taken as the basis.

## AWG in Aerospace and Defence Cables

Cables used in aerospace and defense systems are evaluated not only for electrical performance but also for weight, temperature resistance, mechanical strength and suitability for environmental conditions.

In aircraft Electrical Wiring Interconnection Systems (EWIS) in particular, conductor size and insulation construction are important parameters of system design.

Two cables with the same AWG value may have different insulation materials, voltage ratings, operating temperatures and mechanical properties.

TE Connectivity’s RAYCHEM Spec 44, Spec 55 and FTR16 product families are examples of conductor and insulation constructions for different application requirements.

### TE Connectivity RAYCHEM Spec 44 (44A) cables

Spec 44 is a cable family developed for electronic equipment, avionics systems and wiring applications that require high reliability.

The typical Spec 44 dual-wall insulation construction uses layers of radiation cross-linked polyalkene and modified PVDF. This construction is designed to meet electrical insulation and mechanical and environmental durability requirements together.

Depending on the product variant, different conductor materials, voltage ratings and AWG sizes are available.

Certain products in the Spec 44 family are associated with the historical MIL-W-81044 and the current SAE AS81044 specifications. However, it should not be assumed that every 44A-coded product automatically complies with the military specification.

### TE Connectivity RAYCHEM Spec 55 cables

Spec 55 is a cable family with radiation cross-linked modified ETFE (Ethylene Tetrafluoroethylene) insulation technology.

Available with single-wall and dual-wall insulation options, these products are considered for aerospace, space, defense and high-reliability electronic systems.

Depending on the conductor and plating construction, product options are available in 150 °C and 200 °C temperature ratings.

For example, the M22759/32-22-9 product has:

- a 22 AWG conductor size,
- a tin-plated copper conductor,
- modified ETFE insulation,
- a 600 V voltage rating,
- an operating temperature of -65 °C to +150 °C.
The M22759/32 product designation is associated with the technical specification now maintained as SAE AS22759/32.

### TE Connectivity RAYCHEM FTR16 power cables

Not every cable family is defined with the AWG system.

In TE Connectivity’s RAYCHEM FTR16 power cable family, conductor cross-sections are expressed directly in mm².

FTR16 is a product family with Thermorad insulation technology and a dual-wall power cable construction, intended for applications that require power distribution and mechanical durability.

For example, the FTR16-16-0 product has a 16 mm² conductor cross-section, a 600 VAC voltage rating and an operating temperature of -40 °C to +125 °C.

The value 16 in this product code refers to a 16 mm² conductor cross-section, not 16 AWG.

### Spec 44, Spec 55 and FTR16 compared

- Property
- Spec 44
- Spec 55
- FTR16
- Manufacturer
- TE Connectivity
- Product group
- Equipment and hook-up wire
- Equipment and airframe wire
- Power cable
- Sizing system
- AWG
- mm²
- Insulation technology
- Cross-linked polyalkene / PVDF
- Cross-linked modified ETFE
- Thermorad
- Temperature rating
- 150 °C
- 150 °C / 200 °C depending on variant
- 125 °C
- Related specification
- SAE AS81044 for certain products
- SAE AS22759 for certain products
- To be verified per product.
- Application area
- Electronic and avionics wiring
- Aerospace and defense wiring
- Power distribution systems
The properties in the table show the general technical construction of the product families. Exact electrical, mechanical and environmental properties should be verified using the full part number.

## How to Read the AWG Value in Cable Part Numbers

Cable manufacturers may include properties such as conductor size, insulation type, conductor material, voltage rating and color in their part numbering systems.

This structure can be examined through three different examples from TE Connectivity products.

- Part number (MPN)
- Product family or specification
- Conductor size
- Color
- 44A0211-22-2
- Spec 44
- 22 AWG
- Red
- M22759/32-22-9
- M22759/32 - associated with Spec 55
- 22 AWG
- White
- FTR16-16-0
- FTR16
- 16 mm²
- Black
Although 44A0211-22-2 and M22759/32-22-9 have the same AWG value, they have different insulation constructions and voltage ratings.

In FTR16-16-0, the conductor size is defined in an entirely different sizing system.

For this reason, purchasing, product verification and equivalent evaluation processes should use the manufacturer’s full part number (Manufacturer Part Number - MPN), not just the cable cross-section.

## How to Choose the Right AWG and Cable

When selecting cables for electronic, industrial, aerospace and defense applications, electrical requirements, physical compatibility and the relevant technical specifications should be examined together.

- Selection criterion
- Properties to check
- Conductor size
- AWG or mm², nominal cross-section and conductor resistance
- Conductor construction
- Solid or stranded, number of strands and plating
- Electrical properties
- Operating voltage, continuous current and voltage drop
- Insulation
- Material, insulation thickness and dielectric properties
- Thermal properties
- Operating temperature and derating requirements
- Mechanical properties
- Outer diameter, flexibility, weight and abrasion resistance
- Environmental conditions
- Humidity, vibration, chemical exposure and operating altitude
- Connection compatibility
- Connector contact, crimp terminal and cable seal
- Technical compliance
- Relevant ASTM, SAE, MIL and project specifications
Especially when an alternative product is evaluated to replace an existing cable, having the same AWG value is not sufficient on its own.

In addition to the electrical, thermal, mechanical and environmental properties of the product, the required approval and traceability documents should also be checked.

## Cable and Conductor Solutions for Your Project

Active in electronic components and interconnect products since 1977, Navea Electronics has been TE Connectivity’s authorized distributor in Türkiye since 2001.

It supports its customers in product selection, technical documentation and supply processes when evaluating cables and interconnect components for defense, aerospace, automotive and industrial applications.

When selecting a cable for your project, you can share the required AWG or mm² value, the operating conditions, the relevant technical specification and, if available, the existing manufacturer part number with our team.

To learn more about TE Connectivity cable and interconnect solutions, evaluate your technical requirements and discuss supply options, [you can contact Navea Electronics](https://naveaelectronics.com/en/contact/).

## Frequently Asked Questions

### How many mm² is 22 AWG?

The theoretical cross-sectional area of a 22 AWG conductor is approximately 0.326 mm², and its solid conductor diameter is 0.644 mm. Depending on the nominal calculation and rounding method used, some ASTM tables may show the cross-sectional area as 0.324 mm².

### How many mm² is 18 AWG?

An 18 AWG conductor has a theoretical cross-sectional area of approximately 0.823 mm² and a solid conductor diameter of 1.024 mm.

### How many mm² is 16 AWG?

A 16 AWG conductor has a theoretical cross-sectional area of approximately 1.309 mm² and a solid conductor diameter of 1.291 mm. It is not exactly the same size as a 1.5 mm² metric conductor.

### Does a cable get thicker as the AWG value increases?

No. The AWG system uses an inverse geometric scale. As the AWG number increases, the conductor diameter and cross-sectional area decrease.

### How many amps can a 22 AWG cable carry?

A single current-carrying capacity cannot be set for a 22 AWG cable. The permitted current depends on the conductor material, insulation temperature rating, ambient temperature, installation conditions, cable bundle and the properties of the connecting elements.

### Can cables with the same AWG value replace each other?

Not always. Cables with the same AWG value may have different insulation materials, outer diameters, conductor constructions, voltage ratings and technical compliance documents.

### Is AWG the same as the cable outer diameter?

No. AWG defines the conductor size. The cable outer diameter is the overall physical diameter including the conductor, insulation and, where present, shielding and the outer jacket.

## Related articles

- [What Is a Connector?](https://naveaelectronics.com/en/blog/what-is-a-connector/)
- [What Is Heat Shrink Tubing?](https://naveaelectronics.com/en/blog/what-is-heat-shrink-tubing/)
- [What Is a Relay?](https://naveaelectronics.com/en/blog/what-is-a-relay/)
- [TE Connectivity Distributor in Türkiye](https://naveaelectronics.com/en/blog/te-connectivity-distributor-in-turkiye/)
- [Authorized Distribution and Traceability in Component Sourcing](https://naveaelectronics.com/en/blog/electronic-component-sourcing-traceability/)
- [TE Connectivity products](https://naveaelectronics.com/en/markalarimiz/#te)

### Cookie Preferences

You can enable or disable each category below. Strictly necessary cookies cannot be switched off; all other cookies run only with your active choice.

#### Strictly Necessary Cookies

Required for the basic functions and security of the website and to keep your language preference. These cannot be switched off and are never used for marketing.

#### Functional Cookies

Used to remember your preferences and optimise the website according to your choices.

#### Analytics / Performance Cookies

Help us understand how visitors use the site, identify the most visited pages and detect errors so we can improve performance.

#### Advertising and Tracking Cookies

Used to display content and advertising relevant to your interests and to measure campaign effectiveness. These cookies are not used to identify you.

You can change your preferences at any time via the “Cookie Settings” link in the footer. For details, see the [Cookie Policy and Privacy](https://naveaelectronics.com/en/cerez-politikasi/).